OPERATION
EN
12
Service Manual
P0055 Coffee Machine - 2006
Edition
2006.08.28
Language
English
2.7. AQUA PRIMA
If the “aqua prima” fi lter is selected from the user
menu or the control panel, the system’s water
metering logic functions as follows:
If the “aqua prima” function is enabled, the electronic
control system performs a pulse count of the turbine,
recording one pulse every 2 revolutions.
If the “aqua prima” function is disabled, the electronic
control system performs a pulse count of the turbine,
recording one pulse every revolution.
The graph in the figure below illustrates this
function: