777
The NUOS 80-100-120 litres water
heaters have a low energy absorption
(~300 W) which allows them to be
used together with all other home
appliances without causing
interruptions due to over-absorption
of the domestic electric network.
NUOS transform the traditional
electric water heater in a less impact
product for your doemstic life
Consumption
300 W
3x100 W
Negligible
consumptions
Total
calorific
energy
Electrical energy
Expansion valve
Compressor
DHW inlet
DHW outlet
air outlet
Refrigerant fluid
at liquid status
Air intake
Renewable
energy
Evaporator
Condenser
1 4
2 3
Refrigerant fluid
at gaseous status
WORKING PRINCIPLE
1 - The refrigerant fluid crosses the evaporator and absorbs the heat supplied by the sucked air.
This process ensures that the refrigerant changes phase by evaporating.
2
- The refrigerant gas undergoes, inside the compressor,
a pressure increase which entails the temperature rising.
3 - Inside the condenser, the refrigerant gas gives its heat to the water contained inside the heater.
This exchange process ensures that the refrigerant passes to liquid state by condensing.
4 - The refrigerant fluid looses further pressure and temperature by crossing the expansion valve,
returning to the initial conditions again.