Ariston EURO COMBI 47-116-10 Installation Manual

Browse online or download Installation Manual for Water heaters & boilers Ariston EURO COMBI 47-116-10. Ariston EURO COMBI 47-116-10 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFIG.C.N. 47-116-10 / 47-116-12Servicing InstructionsType C BoilersLEAVE THESE INSTRUCTIONSADJACENT TO THE GAS METER

Page 2 - TABLE OF CONTENTS

10B029Setting the minimum and the maximum power of the boiler1. Check that the supply pressure to the gas valve is a minimum of 20 mbarfor natural gas

Page 3 - INSTRUCTIONS

11B029model 23model 27Regulating the heating power fornatural gas (G20)model 23model 27Regulating the heating power forbutane gas (G30)model 23model 2

Page 4 - Fig. 1.3

12B02910. Remove the pipe from the pressure gauge and connect screw “C” to thepressure outlet in order to seal off the gas.11. Carefully check the pre

Page 5 - Combustion Chamber

13B029Removing the spark generator (SIT Tandem gasvalve)1.Disconnect ignition leads “Q1” by pulling upwards (see fig. 1.30);2.Remove the screws “R1”(s

Page 6 - Fig. 1.17

14B0291.5Access to the Hydraulic CircuitsFig. 1.37UURemoving the D.H.W. (secondary)exchanger1.Remove the screw “U”(see fig. 1.37);2.Push the exchanger

Page 7 - (see fig. 1.21)

15B029Removing the safety valve1.Loosen nut “V”(see fig. 1.38);2.Remove the valve.Removing the automatic air vent1.Unscrew valve “W”(see fig. 1.39).Re

Page 8 - Removing the fan

16B029Removing the pump1.Unscrew “Z” and remove the electrical connection(see fig. 1.41);2.Release the nuts “A1” and remove the pump (see fig. 1.42).R

Page 9 - Servicing and Removal

17B029Removing the expansion vessel1.Remove nut “A3” away from the expansion vessel (see fig. 1.45);2.Remove nut “A4”(see fig. 1.46);3.Remove expansio

Page 10 - Setting gas pressures

18B029Checking fuse1.Remove the inspection panel(see fig. 1.6 - 1.7);2.Remove fuse (see fig. 1.50).1.6Access to the ControlSystemRemoving the time clo

Page 11

19B029Removing the P.C.B.s1.Isolate electricity;2.Remove the front cover of the boiler;3.Remove the inspection panel (see fig. 1.6-1.7);5.Remove the m

Page 12 - 40 50 60 70 80

2B029Page No.1. SERVICING INSTRUCTIONS1.1 Replacement of Parts 31.2 To Gain General Access- Removing the Front Panel 3- Removing the Side Panels 4- To

Page 13 - Fig. 1.31 Fig. 1.32

20B0292. FAULT FINDING1) There is sufficientwater in thesystem2) The gas is turned on3) Theelectricityto theboiler is onPreliminary ChecksMakesure tha

Page 14 - Hydraulic Circuits

21B029DOES THECIRCULATION PUMPCOME ON?YESNONONOYESYESPOWER TOTHE PUMP?DOES THEINSUFFICIENTWATERINDICATORLIGHTCOMEON?(within40 sec.)1) Check for air in

Page 15 - Fig. 1.39

22B029DOES THE FANCOME ON?BOILERSHUTDOWN?ISTHEREPOWERTO THE FAN?NOYESYESYESNOYESNONONO1)Check/replace differentialpressure switch for pump2)Check/repl

Page 16 - Fig. 1.44

23B029DOES THEBURNERLIGHT?YESNOYESYESWASTHERESETSWITCHPRESSED?YESNONONONOYES1)Check/replaceigniterplugs2)Check wiring3) Check starter4)Check small wir

Page 17 - Fig. 1.47

24B029ISTHERE STILL APROBLEM?FUNCTIONSNORMALLYNOYESLISTOFMALFUNCTIONSPOSSIBLE CAUSES123456789Deliveryofhot waterfordomesticuse:when thetapisturnedon,t

Page 18 - Access to the Control

25B029SignallingBoiler OffAuto diagnostic stateSpark ignition stateBoiler functioning normallyLockoutBoiler thermostat satisfiedRoom thermostat/clock

Page 19 - Fig. 1.56

26B0293. ELECTRICALDIAGRAMSLegend:AT = High Voltage P.C.B.BT = Low Voltage P.C.B.B = Flame Failure L.E.D.C = Insufficient Water Pressure L.E.D.D = Wat

Page 20 - 2. FAULT FINDING

27B029EX C-MI/FFI8A/23 MFFI - A/27 MFFI

Page 21 - 2)Replacecirculationpump

28B02990565568 60 5721191236781213111617 18 19 2320 21 22 24 2625888786868987858498851112078163821241221181191121114444901567 59 58611251231071098266

Page 22 - 1) Reset the boiler

29B029573294573520997206573224569236573340573528573727573172571649997208953730952981952610572989572990573343573314571651571652570717564254569387571449

Page 23

3B0291. SERVICING INSTRUCTIONSThe life of individual components vary and they will need servicing orreplacing as and when faults develop.The fault fin

Page 24 - LISTOFMALFUNCTIONS

30B029573294573520997206573224569236573340573528573727573172571649997207953730952981952610572989572990573343573314571651571652570717564254569387571449

Page 25 - Malfunction

31B029573294573520997206573224569236573340573528573727573172571649997207953730952981952610572989572990573343573314571651571652570717564254569387571449

Page 26 - DIAGRAMS

Manufacturer: Merloni TermoSanitari SpA - ItalyCommercial subsidiary: MTS (GB) LIMITEDMTS BuildingHughenden Avenue,High WycombeBucks HP13 5FTTelephone

Page 27 - A/23 MFFI - A/27 MFFI

4B029Removing the side panels1.Remove the screws “B”;2.Pull the panel away from the boiler, then lift the panelup and away from the boiler (see fig. 1

Page 28 - PARTS LIST

1.Remove the side panels of sealed chamber (fig. 1.10);2.Remove the screws “F” of the burner (see fig. 1.11);3.Remove the burner (see fig. 1.12);4.Rem

Page 29

6B029Removing the electrodes 1.Remove rubber gasket “G”(see fig. 1.13);2.Disconnect ignition leads by pulling downward (see fig. 1.14);3.To remove the

Page 30

1.Disconnect the electrical connections “K” and silicone pipes “L” from theirconnection points (see fig. 1.20);2.Remove screws “J” on the top of the s

Page 31

8B0291.Disconnect the silicone pipes “M” and remove the screw “N”(see fig. 1.22);2.Extract the venturi (see fig. 1.23).Removing the venturi device1.Di

Page 32 - 23 99 84 1268 000 - B029

9B0291.4Servicing and Removal of the Gas Valve1234ABCEFDSITTANDEMSITSIGMA1234ABCEFD