Horizontal SolaPlug
Codes HSE175, HS175, HSE200 & HS200
Fitting Instructions
The Horizontal SolaPlug enables up to 4m² of flat plate collector or 30
large tubes to be connected to an existing hot water cylinder, significantly
reducing the cost of a solar installation.
The heat exchanger is sufficiently effective to almost match the perform-
ance of a solar coil.
When fitted to indirect cylinders, the installation is unlikely to have dedi-
cated solar volume, but with the correct backup heating timing perform-
ance will be very close to a new twin coil cylinder.
The homeowner should be aware of the need for correct back up heating
timing to optimise performance.
SolaPlug has full UK Patent Protection & European Pending
SolaPlug Ltd, Hall Farm, Weston, Beccles, Suffolk, NR34 8TT,
Tel: 01502 716810 www.solaplug.co.uk
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Fitting Instructions

Horizontal SolaPlug Codes HSE175, HS175, HSE200 & HS200 Fitting Instructions The Horizontal SolaPlug enables up to 4m² of flat plate collector or

Page 2

Cylinders suited to SolaPlugs Brand / Make Model Indirect Models Direct SolaPlug Albion / Copperform / Kingspan Ultrasteel / Flowmaster AUI120-

Page 3 - Fitting the SolaPlug

Sectioned View Usual orientation with SolaPlug clear of the indirect coil & clear of the inlet pipe. Flow & return from indirect coil Immersio

Page 4 - Conventional Immersion

Apart from Baxi, immersion elements on unvented cylinders have a screw threaded head ( usually 1.75”BSP) & a conventional casing or a separate cov

Page 5

Wrap thread tape around the thread of the pocket & screw it into the upper 1/2” BSP port & tighten with a spanner. Repeat with the immersion e

Page 6 - Complying with MCS

Wiring for Horizontal SolaPlug Immersion stat with cut out Sensor cable leading to con-troller Capillary Screw for securing earthing contacts Mains su

Page 7 - Technical Specification

Technical Specification Description Horizontal SolaPlug 1.75” BSP with & without Immersion Codes HSE175 & HS175 ( E denotes electric

Page 8

Boiler backup heating must be controlled independently of central heating. Backup heating must be timed to come on at the end of the day, when the sun