Ariston GENUS Technical Information Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
37
1 2 4 5 63
ON
AB
C
N203 CN206
C
N201
C
N200
Soft-light
Adjustment
M
ax Heating
Power
Setting the maximum heating circuit power
1. To set the maximum heating circuit power, turn the On/Off knob
t
o the “ON” position and set the time clock and any external
controls to the “ON” position. Turn the knob of the heating
t
hermostat clockwise to maximum.
2. Remove the inspection panel of the P.C.B. and fit a small cross-
head screwdriver in to the right hand potentiometer.
Turn clockwise to increase the pressure or anti-clockwise to
reduce the pressure. Adjust the setting to the required heating
pressure value (displayed on the pressure gauge), as indicated
in
Table B shown on Page 38 .
3. Turn off the boiler by placing the main switch to the "OFF"
position.
Setting the pressure for soft-light ignition.
1. Disconnect the detection electrode connection close to the
P.C.B.
(FIG. 4.1);
2. Start the boiler and during the ignition sequence adjust the left
hand potentiometer until the gas pressure reads the required
gas pressure (see the table on page 38 and 39);
3. Once the gas pressure is set turn off the boiler and re-connect
the detection electrode to the P.C.B.
NB.: It may be necessary to reset the flame failure reset a
number of times during this operation;
4. Remove the pipe from the test point and tighten the screw C
and test for tightness;
5. Carefully check the pressure test points for gas leaks (both inlet
and outlet).