Ariston microGENUS HE 32 MFFI Technical Information Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
After removing the boiler from its packaging, remove the
template from the separate box containing the connection
kit.
N
O
TE
:
Pay particular attention to any test water that
may spill from the appliance.
Place the template in the position the appliance is to be
mounted and after ensur
ing it is hanging squarely
, use it
to drill the holes for the hanging bracket, connection kit
and flue pipe(s) NB: F
or fur
ther information relating to the
flue installation please ref
er to Section 2.9
F
LUE
CONNECTION. (If the appliance is to be fitted on a wall of
combustible material, the wall must be protected by a
sheet of fireproof mater
ial).
If the appliance is to be fitted into a timber framed
building, guidance should be sought from the Institute of
Gas Engineers document R
EF: IGE/UP/7.
2.5.1.
Dr
ill the w
all and plug using those supplied with
the connections kit, position the hanging bracket and
2.5 MOUNTING THE APPLIANCE
FIG. 2.2
In order to allow access to the interior of the boiler for
maintenance purposes, the boiler must be installed in
compliance with the minimum clearances indicated in
FIG. 2.2
2.4 CLEARANCES
LEGEND:
A = Central Heating Flow (3/4”)
B = Domestic Hot
Water Outlet (1/2”)
C = Gas Inlet (3/4”)
D = Domestic Cold
Water Inlet (1/2”)
E = Central Heating Return (3/4”)
2.3 OVERALL DIMENSIONS
FIG. 2.1
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 57 58