1. Disconnect electrical connections “P” and silicone pipe
“Q” (FIG.6.24);
2. Remove screw “R” and remove the fan collar clamp “R”
(
FIG.6.25
);
3. Remove screws “S” (FIG.6.26);
4. Remove fan and mounting plate (FIG.6.27).
6.3.6 Removing the fan
FIG. 6.26
S
S
S
FIG. 6.25
R
FIG. 6.24
P
P
Q
FIG. 6.27
6.4.1. Removing the spark generator
(HONEYWELL Gas Valve)
1. Disconnect ignition leads
“T” by pulling upward
(FIG. 6.28);
2. Remove the screw “U” (FIG. 6.29);
3. Remove the spark generator by pulling forward from
the gas v
alve (F
IG.
6.30).
FIG. 6.28
FIG. 6.29
FIG. 6.30
T
U
6.4 ACCESS TO THE GAS VALVE