B063
Removing the P.C.B.
1.
Isolate electricity;
2. Remove the inspection cover from the reverse of the
control panel;
3. Unplug all electrical connections from the P.C.B. (FIG.
1.65);
4. Remove the screws X1(FIG. 1.66);
5. Separate the facia panel from the rear of the control
panel (FIG. 1.67);
7. Remove the screws Y1 and remove the P.C.B. (FIG.
1.68).
FIG. 1.66
X1
X1
X1
X1
X1
X1
FIG. 1.65
FIG. 1.67
FIG. 1.68
Y1
Y1
64.eps
1187.eps
65.eps
82.eps